4 AO Voltage/Current Module
Key specifications
- 4 AO Voltage/Current Module NJ6100 Nexto Series
- In this context, Nexto Jet is a selection of I/O modules that uses the existing CPUs and modules from Nexto Series to provide the best solution for applications in verticals like infrastructure, building, water, wastewater, food, machines and several OEM
- projects. Nexto Jet is ideal for systems with no hot-swapping and conformal coating requirements. NJ6100 is a module that offers 4 individually configurable voltage or current analog outputs and it is a module that uses one
- Code Description NJ6100 4 AO Voltage/Current Module
- Number of outputs 4 analog outputs Output type Voltage or current output, individually configured
- Configurable parameters Signal type per output Output state indication Yes
- Status and diagnostic indication Display, web pages and CPU’s internal memory Hot swap capability No
- Standards IEC 61131-2
- Mechanical Assembly The mechanical and electrical mounting and the connector pin insertion and removing for single hardware width I/O modules are
- ATTENTION: The CPUs, racks and the PROFIBUS remote head of Nexto Series support the use of Nexto Jet
- Modules. The Nexto Jet is formed by I/Os modules and when used in configuration with CPUs or PROFIBUS remote head of Nexto Series, no other I/O type of Nexto Series can be used in the
- NJ6100. The process data of the module, when inserted in a PROFIBUS network, can be accessed through variables. The table below
- presents the variables organizational structure in the UCP memory. The types of values sent by PROFIBUS are integer and are fixed configured in the ranges -30,000 to +30,000. For instance, in one configured channel as voltage 0 to 10 V, the voltage
- Variable Size- Process Data Description Type Update %QB(n) WORD AO 00 Analog Output 00 INT (Read/ Write) Always
- %QB(n+2) WORD AO 01 Analog Output 01 INT (Read/ Write) Always %QB(n+4) WORD AO 02 Analog Output 02 INT (Read/ Write) Always
- %QB(n+6) WORD AO 03 Analog Output 03 INT (Read/ Write) Always Note:
- Type Set Analog Output Type Voltage 0 - 10 Vdc Not Configured
- larger than the Min Value. The minimum and maximum values for remote PROFIBUS-DP heads are fixed in -30,000 and 30,000.
- NJ6100 has one variable for each output. The parameters minimum value and maximum value are used by the module to convert the engineering value to the analog output value.
- should be removed at least every 6 months. NJ6100 offers important features to assist users during maintenance as: status and diagnostics indicators, web page with